流体机械

2007, No.424(10) 49-53

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Past Issue) | 高级检索(Advanced Search)

加热炉鼓风机频繁故障原因分析及对策
Analysis of the Frequent Troubles of Fumace Blower and its Countermeasure

王雪峰;蔡吉乡;
WANG Xue-feng,CAI Ji-xiang (Sinopec JinLing Petro-Chemical Corporation Alkylbenzene Plant,Nanjing 210046,China)

摘要(Abstract):

某化工厂加热炉热风余热回收系统鼓风机故障率居高不下,通过多次检修,找出了产生故障的原因,并提出了消除故障的措施,实现了鼓风机的平稳运行。
A chemical plant fumace hot-air recovery system for waste heat blower failure rate have reached a high level,After severl times' maintenance,the causes are found out and the measures to eliminate failures are put forward,therefore,the stability operation of the blower is realized.

关键词(KeyWords): 余热回收系统;鼓风机;调节门;轴承;改造
recovery system for waste heat;blower;damper;bearing;reconstruction

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 王雪峰;蔡吉乡;
WANG Xue-feng,CAI Ji-xiang (Sinopec JinLing Petro-Chemical Corporation Alkylbenzene Plant,Nanjing 210046,China)