流体机械

2006, (09) 46-49

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

离心泵试验的误操作及解决措施
Incorrect Manipulations and Solving Measures for the Centrifugal Pump Test

牟介刚,张生昌,艾宁,寿涛
MU Jie-gang,ZHANG Sheng-chang,AI Ning,SHOU Tao(Zhejiang University of Technology

摘要(Abstract):

对离心泵试验中常见的误操作现象进行了详细的分析,指出产生这些误操作的原因,提出了解决这些误操作应采取的具体措施,以开式试验台手动试验为例介绍了在性能试验和汽蚀试验中应采取的正确操作程序。
Familiar incorrect manipulation phenomenons of the centrifugal pump test are analyzed,the causes of these incorrect manipulations are indicated,and material measures that should be taken in solving these incorrect manipulations are put forward.Taking the open-type platform manual test for example,correct manipulative programs that should be taken in performance test and cavitation test are introduced.

关键词(KeyWords): 离心泵;试验;操作方法;操作程序
centrifugal pump;test;manipulative method;manipulative program

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 牟介刚,张生昌,艾宁,寿涛
MU Jie-gang,ZHANG Sheng-chang,AI Ning,SHOU Tao(Zhejiang University of Technology

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享