流体机械

2013, v.41;No.487(01) 68-72

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

同心套管双程流相变蓄热单元蓄放热特性研究
Experimental Study on Heat Charge and Discharge of the Phase Change Thermal Energy Storage Unit with Bushings Between Double Flow

徐峰,田海川,孙勇,师涌江
XU Feng,TIAN Hai-chuan,SUN Yong,SHI Yong-jiang(Hebei Institute of Architecture & Civil Engineering

摘要(Abstract):

采用JDJN-60型相变材料,设计并制作了同心套管双程流相变蓄热单元,利用试验手段对蓄热单元在不同工况下的蓄放热性能进行了研究,分析了传热流体进口温度和流量变化对蓄放热过程的影响。研究结果表明:随着传热流体进口温度的提高,蓄热时间不断减少,但流量增加对蓄热过程影响不大。初步掌握了蓄热单元的蓄放热特性,为其工程应用提供参考依据。
A phase change thermal storage unit,in which JDJN-60 was as phase change material(PCM),with bushings between double flow was designed.The thermal performances of the storage unit in different situations were investigated experimentally.The effects of inlet fluid temperature and flow on the process of heat charge and discharge of the storage unit were analyzed.The results show the time for finishing charging is reduced constantly with improving the inlet temperature of heat transfer fluid.But the flow has little effect.The characteristic of heat charge and discharge of the storage unit was gained.The results offer the reference basis for its engineering application.

关键词(KeyWords): 相变材料;蓄热单元;蓄放热特性
phase change material;thermal storage unit;characteristic of heat charge and discharge

Abstract:

Keywords:

基金项目(Foundation): 河北省教育厅自然科学指令性项目(2009430)

作者(Author): 徐峰,田海川,孙勇,师涌江
XU Feng,TIAN Hai-chuan,SUN Yong,SHI Yong-jiang(Hebei Institute of Architecture & Civil Engineering

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享