脱硫废水离子浓度对管壁结垢行为的影响
Effect of ion concentration of desulfurization wastewater on scaling behavior of tube wall

李仟龙,陈丽娟,魏博,谢伟智,马瑞,宋丽洁,双景轩,王建江
Li Qianlong,Chen Lijuan,Wei Bo,Xie Weizhi,Ma Rui,Song Lijie,Shuang Jingxuan,Wang Jianjiang

摘要(Abstract):

针对脱硫废水引起的管壁结垢问题,通过配置不同浓度离子溶液模拟实际工况,采用挂片沉积法对管壁结垢规律进行试验研究,结合结垢形貌系统分析接触时间与离子浓度对20钢结垢行为的影响。结果表明,挂片在模拟脱硫废水中主要发生CaSO_4结垢,且结垢过程遵循成核-生长机制;Ca~(2+)和SO_4~(2-)浓度的增加会加重结垢;Mg~(2+)浓度在0~4 000 mg/L范围内对结垢起明显的抑制作用,当Mg~(2+)浓度为4 000 mg/L时,相较于0 mg/L结垢量降低了65.3%,但浓度高于4 000 mg/L后反而会加重结垢;Cl~-浓度在20 000 mg/L之前结垢量缓慢减少,进一步增加时结垢量显著增加,Cl~-浓度为35 000 mg/L时较20 000 mg/L结垢量增加了74.2%。实际生产中,建议将Mg~(2+)和Cl~-浓度分别控制在4 000 mg/L和20 000 mg/L以下,以减缓管壁的结垢情况。研究可为脱硫废水处理工艺参数优化与高效防垢技术开发提供参考。
Aiming at the problem of tube wall scaling caused by desulfurization wastewater,the actual working conditions were simulated by configuring different concentration ion solutions.An experimental study on the scaling pattern of pipelines was conducted using the hanging-film deposition method.Combined with the scaling morphology,the effects of contact time and ion concentration on the scaling of 20 steel were systematically investigated.The results indicate that the main scaling phenomenon occurring on the coupon in simulated desulfurization wastewater is CaSO_4 scaling,which follows a nucleation-growth mechanism.The increase of Ca~(2+) and SO_4~(2-) concentration will aggravate the scaling.Mg~(2+) had a significant inhibitory effect on scaling at 0~4 000 mg/L,when the concentration of Mg~(2+) is 4 000 mg/L,the fouling amount is reduced by 65.3% compared with that of 0 mg/L,but it would still aggravate scaling when the concentration was higher than 4 000 mg/L.Before the Cl~- concentration reaches 20 000 mg/L,the amount of scaling decreases slowly.When the Cl~- concentration increases further from 20 000 mg/L,the amount of scaling increases significantly,when the concentration of Cl~- was 35 000 mg/L,the fouling amount increased by 74.2% compared with that of 20 000 mg/L.In actual production,it is recommended to control the concentration of Mg~(2+) below 4 000 mg/L and the concentration of Cl~- below 20 000 mg/L to mitigate tube wall scaling.The research can provide reference for the optimization of wastewater treatment process parameters and the development of efficient anti-scaling technology.

关键词(KeyWords): 脱硫废水;20钢;结垢;垢层形貌
desulfurization wastewater;20 steel;scaling;scale layer morphology

Abstract:

Keywords:

基金项目(Foundation): 国家自然科学基金项目(52261022);; 高校青年教师科研创新能力支持项目(SRICSPYF-BS2025042);; 国家级大学生创新训练计划项目(202510755044)

作者(Author): 李仟龙,陈丽娟,魏博,谢伟智,马瑞,宋丽洁,双景轩,王建江