横流闭式冷却塔的试验研究
Experimental Research on Cross-closed Cooling Tower

颜健;刘妮;欧阳新萍;章立新;李辉;
YAN Jian,LIU Ni,OUYANG Xin-ping,ZHANG Li-xin,LI Hui(University of Shanghai for science and technology,Shanghai 200093,China)

摘要(Abstract):

介绍了一种新型的冷却塔——横流闭式冷却塔试验研究,通过试验得到了影响横流闭式冷却塔性能的主要因素,并经过分析得出了这些因素对其性能的影响规律,提出了优化横流闭式冷却塔设计的几点建议。
A new cooling-tower——cross-closed cooling tower was introduced,the effecting factors to the performance of cross-closed cooling tower were achieved by experimental research,and get the law which can express the factors how to effect the cool-tower′s performance was found out.In the end,some advices were given to improve the methods todesign cooling-tower.