生物型添加剂对改善空调器性能的应用研究Preparatory Study on Biologic Additive for Performance Improvement of Air-conditioner
李国云,王芳,刘颖,邬志敏
LI Guo-yun,WANG Fang,LIU Ying,WU Zhi-min(University of Shanghai for Science and Technology
摘要(Abstract):
在空调器中加入一定量的添加剂后,在焓差实验室中对其进行性能测试。测试了它的制冷量、功率以及排气温度等性能参数,并与相同工况下未加入添加剂时的测试结果进行了对比分析。实验表明,加入不同剂量的生物型润滑油添加剂后,换热器传热效果有所改善,空调系统的排气温度、功耗降低,而制冷量升高,COP平均增大11.62%,达到了提高空调器性能和节能的目的。
After put into some biologic additive,the air-conditioner system is tested in an enthalpy lab.The refrigerating power and the compressor discharge temperature will be tested in order to compare with them without additive.From the experiment data,the lubricant oil additive can improve the performance of heat transfer on the tested air-conditioner with decreasing the discharge temperature as well as energy consumption.Then the system's COP is up to 11.62% in average,so the energy of the refrigeration unit has been saved.
关键词(KeyWords):
生物型添加剂;油膜;空调器性能;强化换热;节能
biologic additive;lubricant oil film;air-conditioner performance;heat transfer enhancement;energy-saving
基金项目(Foundation): 上海市重点学科建设项目(T0503);; 上海市教委发展基金项目(05EZ25)
作者(Author):
李国云,王芳,刘颖,邬志敏
LI Guo-yun,WANG Fang,LIU Ying,WU Zhi-min(University of Shanghai for Science and Technology
参考文献(References):
- [1]魏龙.冷冻机油对压缩式制冷系统的影响及选择[J].压缩机技术,2001,170(6):18-20.
- [2]加藤忠纪,华志宏.冷冻机油与制冷剂[Z].CFC替代技术专辑,2000,(2):31-34.
- [3]胡浩,孟建军,梁爽,等.房间空调器用滚动转子式压缩机回油问题的研究[J].制冷技术,2000,(2):13-16.
- [4]邱嘉昌,刘龙昌.极化冷冻油添加剂[J].制冷技术,2003,(3):38-41.
- [5]杜世春,王芳,邬志敏.多功能人工环境试验室的研制和试验分析[J].制冷与空调,2005,5(3):74-78.
- [6]王芳,邬志敏,李征涛.空调器部件测试与性能匹配试验系统的研制与分析[A].第三届制冷空调新技术进展会议论文集[C].杭州,2005,4:560-564.