冷热负荷非平衡地区土壤源热泵土壤热失衡研究现状及其关键问题Research Status and Key Problem of Underground Thermal Unbalance of Ground Coupled Heat Pump Operated in Districts with Unbalanced Cooling and Heating Load
杨卫波,张苏苏
YANG Wei-bo,ZHANG Su-su
摘要(Abstract):
土壤热失衡是土壤源热泵在冷热负荷非平衡地区应用中出现的一种常见问题,是影响其长期高效稳定运行及正确推广与健康发展的关键。本文在阐述土壤热失衡概念、由来及其危害的基础上,详细分析了土壤热失衡问题的国内外研究现状,提出了其设计方案,并给出了土壤热失衡控制中有待解决的关键问题,可为土壤源热泵的相关研究及其实际应用提供参考。
Underground thermal imbalance is a common problem in ground coupled heat pump( GCHP) system operated in districts with unbalanced cooling and heating load,and become a critical problem for the long term efficient operation of GCHP system and its correct spread and development. Based on the analysis of concept,causes and possible endanger of underground thermal imbalance,the research status of underground thermal imbalance at home and abroad were analyzed in detail. The design schemes for soling the underground thermal imbalance were presented,and the key problem in controlling underground thermal imbalance were pointed out. This can provide a guide for related research and application of GCHP.
关键词(KeyWords):
冷热负荷非平衡地区;土壤源热泵;土壤热失衡;关键问题
districts with unbalanced cooling and heating load;ground-coupled heat pump;underground thermal imbalance;key problem
基金项目(Foundation): 住房与城乡建设部科技计划资助项目(2008-K1-26);; 江苏省科技支撑计划资助项目(BE2010699);; 江苏省政府留学基金资助项目(2010年度);; 广西建筑新能源与节能重点实验室(桂林理工大学)开放基金(11-03-21-15);; 扬州大学“新世纪人才工程”优秀青年骨干教师计划资助项目(2008年度);; 扬州大学科技创新培育基金项目(2012CXJ047)
作者(Author):
杨卫波,张苏苏
YANG Wei-bo,ZHANG Su-su
参考文献(References):
- [1]匡耀求,黄宁生,朱照宇,等.大地热流——影响西部环境与生态演变的重要自然因素[J].矿物岩石地球化学通报,2002,21(1):30-34.
- [2]盛连喜.环境生态学导论(第2版)[M].北京:高等教育出版社,2009.
- [3]Commercial/institutional ground-source heat pump engineering manual[M].Atlanta:American Society of Heating Refrigerating and Air-conditioning Engineerings,Inc,1995.
- [4]Gilbreath C S.Hybrid ground source heat pump system for commercial application[D].Master’s thesis.University of Alabama.Tuscaloosa.1996.
- [5]Kavanaugh S P.A design method for hybrid groundsource heat pumps[J].ASHRAE Transactions,1998,104(2):691-698.
- [6]Phetteplace G,Sullivan W.Performance of a hybrid GCHP system[J].ASHRAE Transactions,1998,104(1):763-770.
- [7]Singh J B,Foster G.Advantages of using the hybrid geothermal options[M].The second Stockton College of New Jersey,1998.
- [8]Chiasson A D,Spitler J D,Rees S J.A model for simulating the performance of a pavement heating system as a supplemental heat rejecter with closed loop ground source heat pump systems[J].ASME Journal of Solar Energy Engineering,2000,122(11):183-191.
- [9]Chiasson A D,Spitler J D,Rees S J.A model for simulating the performance of a shallow pond as a supplemental heat rejecter with closed loop ground source heat pump systems[J].ASHRAE Transactions,2000,106(2):107-121.
- [10]Yavuzturk C and Spitler J D.Comparative study of operating and control strategies for hybrid ground source heat pump systems using a short time step simulation model[J].ASHRAE Transactions,2000,106(2):192-209.
- [11]Ramamoorthy M,Jin H,Chiasson A,et al.Optimal sizing of hybrid ground-source heat pump systems that use a cooling pond as a supplemental heat rejecter-A system simulation approach[J].ASHRAE Transactions,2001,107(1):26-38.
- [12]Liu X,S J Rees,J D Spitler.Modeling snow melting on heated pavement surfaces.Part II:Experimental validation[J].Applied Thermal Engineering,2007,27:1125-1131.
- [13]Man Y,Yang H X,Wang J G.Study on hybrid ground-coupled heat pump systems for air-conditioning in hot-weather areas like Hong Kong[J].Applied Energy,2010,87:2826-2833.
- [14]Scott Hackel,Gregory Nellis,Sanford Klein.Optimization of cooling-dominated hybrid ground coupled heat pump systems[J].ASHRAE Transactions,2009,115(1):565-580.
- [15]舒海文,端木琳,华蓉,等.寒冷地区土壤源热泵冷热源系统设计方案研究[J].太阳能学报,2008,29(11):1375-1379.
- [16]Chiasson A D,Yavuzturk C C,Johnson D W,et al.Optimization of the ground thermal response in hybrid geothermal heat pump systems[J].ASHRAE Transactions,2010,116(1):512-524.
- [17]Sagia Z,Rakopoulos C,Kakaras E.Cooling dominated Hybrid Ground Source Heat Pump System application[J].Applied Energy,2012,94:41-47.
- [18]Cui P,Yang H X,Spitler J D,et al.Simulation of hybrid ground-coupled heat pump with domestic hot water heating systems using HVACSIM+[J].Energy and Buildings,2008,40:1731-1736.
- [19]Li S H,Yang W H,Zhang X S.Soil temperature distribution around a U-tube heat exchanger in a multi-function ground source heat pump system[J].Applied Thermal Engineering,2009,29:3679-3686.
- [20]Yu X,Wang R Z,Zhai X Q.Year round experimental study on a constant temperature and humidity airconditioning system driven by ground source heat pump[J].Energy,2011,36:1309-1318.
- [21]李满峰,周国峰,范波.土壤源热泵系统冷凝热回收的优化研究[J].低温与超导,2010,38(1):61-66.
- [22]胡晓伟,施孝增,张海东,等.热回收降低地源热泵冷热不平衡的研究[J].建筑热能通风空调,2010,29(2):49-52,20.
- [23]张娟娟,程小菲,沈致和.地源热泵系统的热回收分析[J].建筑节能,2011,25(1):80-82.
- [24]Chiasson A D,Yavuzturk C.Assessment of the viability of hybrid geothermal heat pump system with solar thermal collector[J].ASHRAE Transactions:Symposia KC-03-3-3,2003:487-499.
- [25]余延顺,廉乐明.寒冷地区太阳能-土壤源热泵系统运行方式的探讨[J].太阳能学报,2003,24(1):111-115.
- [26]Bi Y H,Guo T W,Zhang L,et al.Solar and ground source heat pump system[J].Applied Energy,2004,78:231-245.
- [27]Ozgener O,Hepbasli A.Performance analysis of a solar assisted ground-source heat pump system for greenhouse heating:an experimental study[J].Building and Environment,2005,40:1040-1050.
- [28]Trillat-Berdal V,Souyri B,Fraisse G.Coupling of geothermal heat pumps with thermal solar collectors[J].Applied Thermal Engineering,2007,27(10):1750-1755.
- [29]Han Z W,Zheng M Y,Kong F H,et al.Numerical simulation of solar-assisted ground source heat pump heating system with latent heat energy storage in severely cold area[J].Applied Thermal Engineering,2008,28:1427-1436.
- [30]Kjellsson E,Hellstrom G,Perers B.Optimization of systems with the combination of ground-source heat pump and solar collectors in dwellings[J].Energy,2010,35(6):2667-2673.
- [31]Wang X,Zheng M Y,Zhang W Y,et al.Experimental study of a solar-assisted ground-coupled heat pump system with solar seasonal thermal storage in severe cold areas[J].Energy and Buildings,2010,42:2104-2110.
- [32]Yang W B,Shi M H,Dong H.Numerical simulation of the performance of a solar-earth source heat pump system[J].Applied Thermal Engineering,2006,26(18):2367-2376.
- [33]Yang Weibo,Chen Zhenqian,Shi Mingheng.The alternate operation characteristics of a solar-ground source heat pump system[J].Journal of Southeast University(English Edition),2010,26(2):327-332.
- [34]杨卫波,倪美琴,施明恒.太阳能-地源热泵系统运行特性的试验研究[J].流体机械,2009,37(12):52-57.
- [35]Li X G,Chen Z H,Zhao J.Simulation and experiment on the thermal performance of U-vertical ground coupled heat exchanger[J].Applied Thermal Engineering,2006,26:1564-1571.
- [36]朱娜.地源热泵地埋管换热系统热堆积分析[D].武汉:华中科技大学,2007.
- [37]李明.地下蓄能时变特性及其能量特征分析[D].长春:吉林大学,2007.
- [38]Gao J,Zhang X,Liu J,et al.Thermal performance and ground temperature of vertical pile-foundation heat exchangers:A case study[J].Applied Thermal Engineering,2008,28:2295-2304.
- [39]Fan R,Jiang Y Q,Yao Y,et al.Theoretical study on the performance of an integrated ground-source heat pump system in a whole year[J].Energy,2008,33:1671-1679.
- [40]马娟.土壤耦合热泵系统的长周期运行特性研究[D].南京:南京理工大学,2009.
- [41]Lazzari S,Priarone A,Zanchini E.Long-term performance of BHE(borehole heat exchanger)fields with negligible groundwater movement[J].Energy,2010,35:4966-4974.
- [42]王松庆,张旭,鲍谦,等.负荷不平衡率对不同地埋管布置形式下土壤温度场影响的研究[J].建筑科学,2010,26(8):64-67.
- [43]杨卫波,施明恒,陈振乾.非连续运行工况下垂直地埋管换热器的换热特性[J].东南大学学报:自然科学版,2013,43(2):328-333.
- [44]杨卫波,施明恒,陈振乾.基于准三维模型的垂直U型埋管换热特性影响因素的分析[J].流体机械,2012,40(4):4-70.
- [45]杨卫波,王松松,刘光远,等.土壤源热泵地下埋管传热强化与控制的试验研究[J].流体机械,2012,40(10):40,70-76.
- [46]齐洪洋,高磊,张莹莹,等.管壳式换热器强化传热技术概述[J].压力容器,2012,29(7):77-82.
- [47]Jung Chan Choi,Joonsang Park,Seung Rae Lee.Numerical evaluation of the effects of groundwater flow on borehole heat exchanger arrays[J].Renewable Energy,2013,52:230-240.
- [48]Weibo Yang,Yongping Chen,Mingheng Shi,et al.Numerical investigation on the underground thermal imbalance of ground-coupled heat pump operated in cooling-dominated district[J].Applied Thermal Engineering,2013,58:626-637.