流体机械

2004, (10) 64-66

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

地下水源热泵代替燃油锅炉供热的经济性分析
Economical Analysis on Substitute Ground Water Heat Pump Instead of Fuel Boiler in Heating System

刘东,由世俊
LIU Dong;YOU Shi-jun (Tianjin University;

摘要(Abstract):

以胜利油田某供暖小区为例 ,对燃煤锅炉、燃油锅炉、电锅炉、地下水源热泵为热源的几种方案进行了分析比较 ,认为用地下水源热泵系统代替燃油锅炉是可行的 ,而且是经济的 ;介绍了工程设计和运行的具体情况 ,指出了地下水源热泵系统的特点和使用时的限制条件
Heating region in Shengli oil field is analyzed to compare different heating system with heat source of coal-fired-boiler, oil-fired-boiler, electrical boiler or ground water heat pump.It is considered that it is feasible and economical to select ground water heat pump instead for the oil-fired-boiler.The design and operating of the rebuild project are briefly introduced and the specialties and restructions of the ground water heat pump heat system are indicated.

关键词(KeyWords): 地下水源;燃油锅炉;经济性
ground water;oil-fired-boiler;economical