冷却塔折流板除雾器叶片折角优化数值模拟Impact of Bend Angle on Removal Efficiency of Cooling Tower Wave-plate Mist Eliminator by Numerical Simulation
张恩实;王飞飞;
ZHANG En-shi;WANG Fei-fei;Huazhong University of Science and Technology;
摘要(Abstract):
为探究冷却塔折流板除雾器不同物理参数(叶片转折角度、气流流速、液滴粒径等)与除雾效率的关系,本文采用SST k-ω模型和Euler/Lagrange方法对梯形折流板除雾器内气液两相流动进行二维数值模拟。结果表明,折流板除雾器对粒径小于10μm的液滴除雾效率较低;随着叶片转折角度的减小,折流板除雾器的除雾效率和压降均有所上升;对于本文研究的不同结构的折流板,当除雾器的效率相同时,叶片折角为α=45°的除雾器所需的功耗最低,是最佳选择。在实际工程应用中,折流板的选取应对除雾效率与气流压降进行综合考虑。
This paper numerically investigates the relationship between removal efficiency and various parameters of cooling tower wave-plate mist eliminator,i.e.,bend angle(α),gas velocity and droplet diameter,2 D numerical simulation was carried out on the gas-liquid two-phase flow in the trapezoidal wave-plate mist eliminator by using SST k-ω model and Euler/Lagrange method. The results show that,for droplets with diameter less than 10μm,the removal efficiency of the wave-plate mist eliminator was relatively low. Moreover,both the removal efficiency and pressure drop of the mist eliminator increased somewhat with decrease of the bend angle. For the wave-plates of different constructions in present study,when the removal efficiencies of mist eliminators are the same,the power consumption required by the mist eliminator with the bend angle of α=45°is lowest and is the best choice. In the practical engineering applications,comprehensive consideration should be given to both the removal efficiency and pressure drop in the selection of wave-plates.
关键词(KeyWords):
冷却塔;折流板除雾器;数值模拟;除雾效率;除雾器压降
cooling tower;wave-plate mist eliminator;numerical simulation;removal efficiency;pressure drop
基金项目(Foundation): 国家自然科学基金项目(51506069);; 中央高校基本业务费资助项目(HUST2015069,2016YXMS286)
作者(Authors):
张恩实;王飞飞;
ZHANG En-shi;WANG Fei-fei;Huazhong University of Science and Technology;
参考文献(References):
- [6]Galletti C,Brunazzi E,Tognotti L.A numerical model for gas flow and droplet motion in wave-plate mist eliminators with drainage channels[J].Chemical Engineering Science,2008,63(23):5639-5652.
- [7]Ghetti S.Investigation of entrainment phenomena in inertial separators[D].MS Thesis,University of Pisa,2003,Pisa,Italy.
- [8]郝雅洁.湿法烟气脱硫除雾效率和流场优化的数值模拟研究[D].南京:东南大学,2015.
- [9]张楠,李念平,崔海蛟,等.无填料冷却塔冷却性能的研究[J].流体机械,2017,45(9):56-59.
- [10]Zamora B,Kaiser A.Comparative efficiency evaluations of four types of cooling tower drift eliminator,by numerical investigation[J].Chemical Engineering Science,2011,66(6):1232-1245.
- [1]Phillips H,Deakin A W.Measurements of the collection efficiency of various demister devices[R].Proceedings of the Fourth Annual Meeting of the Aerosol Society,Loughborough,1990.
- [2]王政允.湿法脱硫系统除雾器除雾特性的试验研究与数值模拟[D].北京:华北电力大学(北京),2009.
- [3]黄新长.脱硫除雾器性能试验研究与优化设计[D].北京:华北电力大学(北京),2010.
- [4]Wang Y,James P W.Assessment of an eddyinteraction model and its refinements using predictions of droplet deposition in a wave-plate demister[J].Chemical Engineering Research&Design,1999,77:692-698.
- [5]Sriveerakul T,Maclaine-cross I,Behnia M.Performance Prediction for Cooling Tower Eliminators[R].17th Annual Conference of Mechanical Engineering Network,2003.(下转第53页)
- 冷却塔
- 折流板除雾器
- 数值模拟
- 除雾效率
- 除雾器压降
cooling tower - wave-plate mist eliminator
- numerical simulation
- removal efficiency
- pressure drop