流体机械

2007, No.418(04) 9-11

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

轧槽管的污垢特性及其防垢性能实验研究
Experimental Investigation of Fouling Characteristics and Fouling Prevention in Corrugated Tube

朱冬生,曾力丁,钱颂文
ZHU Dong-sheng,ZENG Li-ding,QIAN Song-wen(South China University of Technology

摘要(Abstract):

在综述管壳式换热器和板式换热器国内外污垢研究的基础上,介绍了轧槽管防垢性能实验和污垢模型,轧槽管的污垢热阻为光管的0.52~0.88倍,污垢条件下的传热Nu数为光管的1.8倍。轧槽管污垢热阻为流速的函数,当流速由0.25m/s增至0.75m/s时,污垢热阻减小至原来的66.7%。
Basing on the review of the investigations of fouling in shell-and-tube heat exchanger and plate heat exchanger,the experimental investigation of fouling prevention in corrugated tubes and the fouling models was introduced.Experimental investigation shows that the heat resistance of fouling in corrugated tube is 0.52~0.88 times that of smooth tube.The Nusellt number is 1.8 times that of smooth tube.The heat resistance of fouling in corrugated tube is majorant of fluid velocity.When the other parameter values are same,the fluid velocity increases from 0.25 m/s to 0.75 m/s,the heat resistance of fouling will reduce to 66.7%.

关键词(KeyWords): 轧槽管;污垢;污垢热阻;换热器
corrugated tube;fouling;heat resistance of fouling;heat exchanger

Abstract:

Keywords:

基金项目(Foundation): 教育部新世纪优秀人才支持计划(NCET040826);; 清洁高效冷却装备的研制及产业化,广东省重大科技攻关项目(2005A30303001)

作者(Author): 朱冬生,曾力丁,钱颂文
ZHU Dong-sheng,ZENG Li-ding,QIAN Song-wen(South China University of Technology

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网
分享