地源热泵地下换热系统热响应测试及分析Test and Analysis of Thermal Response of the Ground Heat Exchanger System Used in the Ground Source Heat Pump
李芃,王健,陈汝东,雷刚
LI Peng1,WANG Jian1,CHEN Ru-dong1,LEI Gang2(1.Tongji University
摘要(Abstract):
土壤源热泵的应用具有地域特性,不仅不同地区应用情况不同,就是同一地区因地质条件的差异而有所不同,所以土壤特性的测试工作十分重要。本文根据上海某展示中心项目地下换热系统测试,对地埋管换热器系统的热响应进行了测试和分析。
The application of ground source heat pump is of geographical features,not only the application is different in the different regions,but also in the same region for the different geological conditions.So the test of the soil characteristics is very important.In this paper,the ground heat exchanger system design advice is provided according to a ground heat exchanger system test of a Shanghai Exhibition Center projects.
关键词(KeyWords):
土壤源热泵;节能;地下换热系统测试
ground-source heat pump;energy conservation;the ground heat exchanger system test
基金项目(Foundation):
作者(Author):
李芃,王健,陈汝东,雷刚
LI Peng1,WANG Jian1,CHEN Ru-dong1,LEI Gang2(1.Tongji University
参考文献(References):
- [1]徐伟.地源热泵工程技术指南[M].北京:中国建筑工业出版社,2001.
- [2]中国建筑科学研究院.GB50366-2005地源热泵系统工程技术规范[S].
- [3]GB50189-2005.公共建筑节能设计标准[S].
- [4]国际地源热泵协会.闭环地源热泵系统设计与安装指南[Z].
- [5]Li Peng,Qiu Zhong-Zhu.Studies on refrigerating per-formance of the Ground Heat Pump with U-shapedvertical loop of pipe[A].Proceedings of InternationalSymposium on ACHR[C].Shanghai,2000.28-34.