14000Nm~3/h制氧机主换热器改造Main Heat Exchanger Modification for the 14000Nm~3/h Oxygen-producing Device
王林平
WANG Lin-ping (Oxygen Producing Factory
摘要(Abstract):
分析了2#14000Nm3/h制氧机在投产时存在的板式热端温差大的问题;并利用检修的机会,在板式冷箱内增加了一台主板式换热器以解决换热面积不足的问题。检修后发现,氧、氮、氩产量纯度得到了大幅地提升。
The temperature difference at warm end of the No2 14000Nm3/h oxygen producing device was large when it was put into production.A main heat exchanger was added to the ice chest during checking and repairing,the problem of insufficient heat-exchange area was solved.Purity of oxygen,nitrogen and argon is increased eividently after checking and repairing.
关键词(KeyWords):
主换热器;热端温差;冷损;原因;处理
main heat exchanger;temperature difference at warm end;cold loss;cause;solution
基金项目(Foundation):
作者(Author):
王林平
WANG Lin-ping (Oxygen Producing Factory