R417A热泵空调器运行特性分析Analysis of Running Performance of Heat Pump Type Air Conditioner Using R417A
张威,刘颖,薛梅
ZHANG wei,LIU ying,XUE mei (University of Shanghai for Science and Technology
摘要(Abstract):
在焓差实验台和热泵性能测试系统中,对1台R417A热泵空调器在高/低温工况下的运行特性进行研究。通过改变蒸发器侧空气的温度、湿度等参数,测定了不同工况下空调器的各项性能指标。结果显示R417A热泵空调器的排气温度相对较低,制冷系统的冷凝温度、蒸发温度、制热系数和功耗在高温工况时变化不大,低温工况时,由于室外侧翅片管蒸发器结霜系统各性能变化较大,在结霜后期系统的性能有较大的衰减。
Using air-enthalpy test box and heat pump performance test system,evaluates the running performance of a R417A air-conditioner at high and low temperature condition with.By changing the temperature and humidity of the air on the evaporator side,records the temperature in and out the compressor,evaporation and condensation temperature,COP,and races dynamically the frost formation process on the flat-fin surface of an outdoor heater exchanger with a numeral camera.The results show that the outlet temperature of compressor at the high and low temperature condition is much lower in the R417A air condition,the changing of the condensation temperature,evaporation temperature,COP and power consumed at high temperature condition is less,the change of every aspect at low temperature condition is biggest because the frost on the flat-fin surface,the performance of the air-conditioner at the end of frost period is much worse.
关键词(KeyWords):
R417A;翅片管蒸发器;运行特性;结霜
R417A;fin-and-tube evaporator;running performance;frost
基金项目(Foundation): 上海市重点学科建设项目(S30503)
作者(Author):
张威,刘颖,薛梅
ZHANG wei,LIU ying,XUE mei (University of Shanghai for Science and Technology
参考文献(References):
- [1]Jamesmcalm.R-22的替代现状[J].制冷与空调,2005,5(1):62-69.
- [2]陈九法.关于R407C用于替代R22的研究[J].流体机械,2004,32(8):69-72.
- [3]石泳,厉彦忠.R12、R22替代工质对制冷系统性能的影响[J].制冷与空调,2002,2(4):57-61.
- [4]杜邦公司实验数据.www.dupont.com.
- [5]Senshu T,et al.Heat pump performance under frostingcondition:Part heat and mass transfer on cross2finnedtube heat exchangers under-frosting condition[J].ASHRAE Trans.,1990,96(Part 1):324-329.
- [6]Yasuda H,et al.Heat pump performance under frostingcondition:Part II-simulation of heat pump cycle char-acteristics under frostingcondition[J].ASHRAETrans.,1990,96(Part 1):330-336.
- [7]Rite RW,Crawford R R.Parametric study of the factorsgoverning the rate of frost accumulation on domestic re-frigerator2freezer finned2tube evaporator coils[J].ASHRAE Trans.,1991,97(Part 2):438-446.
- [8]Jhee S,Lee K S,Kim W S.Effect of surface treatmentson the frosting/defrosting behavior of a fin-tube heatexchanger[J].Int.J.Re-frig.,2002,25:1047-1053.
- [9]张铁雁,姜俊明,陈建民,等.中华人民共和国国家质量监督检验检疫总局,中国国家标准化管理委员会发布.房间空气调节器(GB/T7725-2004)[S].北京,2004.
- [10]韩志涛.空气源热泵冷水机组夏季运行工况的模拟与分析[D].哈尔滨:哈尔滨工业大学,2002:26-31.
- [11]李雪,高强.R417A的应用现状与展望[J].制冷与空调,2007,7(34):35-38.
- [12]张小艳,袁秀玲,田怀璋.R417A在螺纹管中换热特性研究[J].西安交通大学学报,2007,41(1):21-27
- [13]李晓燕,闫泽生.R417A在热泵热水器系统中替代R22的实验研究[J].制冷学报,2003,24(4):1-4.
- [14]张明方,李鹏荣.R417A替代家用空调器用R22的实验研究[J].制冷与空调,2006,6(5):80-82.
- [15]Arpea C,Renno C.Experimental comparison of R22 withR417Aperformance in a vapor compression refrigeration-plant subjected to a cold store[J].Energy Conversionand Management,2004,32(4):43-47.