首先对现有采暖空调系统的输送能耗状况及其存在的问题做了深入分析,采暖空调系统的输送系统可等效为异程或者同程式水力模型。然后分别对异程或者同程式水力模型的能量模型、温度模型及压力模型做了深入研究,发现采暖空调系统的设计模型是导致输送系统"大流量、小温差、高功耗"的根本原因。最后提出一种新型空调输送系统的解决方案——双冷源串联两管制空调系统,该系统通过提高输送系统设计供回水温差的方法解决输送系统"大流量、小温差、高功耗",不仅有效地解决了输送系统"大流量、小温差、高功耗"的问题,而且提高了冷源的效率。
First,the delivery energy consumption and existing problems of the existing heating and air-conditioning system are analyzed.For further analysis,the delivery system of the heating and air-conditioning system can be equivalent to the direct return or reverse return hydraulic model.Second,through the study of energy model,temperature model and pressure model of the direct return and reverse return hydraulic model,it is found the design model of the heating and air conditioning system is the root cause for "large flow,small temperature difference and high power consumption" of the delivery system.At last,a new solution of the air-conditioning delivery system is put forward,which is the tandem double-pipe air conditioning system with double cooling sources.This system solves the problem of "large flow,small temperature difference and high power consumption" of the delivery system by improving the design supply and return water temperature difference of the delivery system.It not only effectively solves the problem of "large flow,small temperature difference and high power consumption" of the delivery system,but also raises the efficiency of cooling source.
关键词(KeyWords):
异程式水力模型;同程式水力模型;大流量小温差;双冷源串联两管制空调系统
direct return hydraulic model;reverse return hydraulic model;large flow and small temperature difference;tandem double-pipe air-conditioning system with double cooling source
基金项目(Foundation): 2015年浙江省建设科研项目(2015K55)
作者(Author):
毛颖杰,田向宁
MAO Yingjie,TIAN Xiangning
参考文献(References):
- [1]谢湘鄂.动力分散型空调水系统管网水力特性研究[D].武汉:华中科技大学,2013.XIE X E.Study on hydraulic characteristics of power distributed conditioning water system pipe line[D].Wuhan:Huazhong University of Science & Technology,2013.
- [2]刘猛.空调冷冻水管网特性研究[D].上海:东华大学,2013.LIU M.research on air conditioning chilled water piping network[D].Shanghai:Donghua University,2013.
- [3]RISHEL J B.Twenty-five years' experience with variable speed pumps on hot and chilled water systems[J].ASHRAE Transactions,1989,94(21):74-80.
- [4]WILLIAM P B,ERIC B P.Varying views on variable primary flow chilled water systems[J].HPAC Engineering,2004,76(3):5-9.
- [5]李连生,赵远扬.适应建筑能耗测试与评定的ISO/TC86技术标准发展展望[J].流体机械,2016,44(10):70-72.LI L S,ZHAO Y Y.Development trends of technical standardization adapted for testing and rating of building energy performances for ISO/TC86[J].Fluid Machinery,2016,44(10):70-72.
- [6]蒋小强,龙惟定,王民,等.空调水系统变流量的运行特性[J].流体机械,2010,38(3):71-75.JIANG X Q,LONG W D,WANG M,et al.Energy-efficiency performance with variable air-conditioning water flow rate[J].Fluid Machinery,2010,38(3):71-75.
- [7]陈文凭,杨昌智,余院生.基于冷水机组性能曲线的中央空调水系统优化控制[J].流体机械,2008,36(8):73-78.CHEN W P,YANG C Z,YU Y S.Optimal control of building HVAC&R system based on chiller's performance curve[J].Fluid Machinery,2008,36(8):73-78.
- [8]贾晶,袁从杰,刘坤.空调水系统优化方案与离心式冷水机组节能技术[J].流体机械,2006,34(6):82-86.JIA J,YUAN C J,LIU K.Optimization proposal of chilled water system and energy conservation technology of centrifugal chiller[J].Fluid Machinery,2006,34(6):82-86.
- [9]WILLIAM P B,ERIC B P.Energy use and economic comparison of chilled water pumping system alternatives[J].ASHRAE Trans,2006,112:198-208.
- [10]田向宁,毛颖杰,李翠敏.双冷源梯级空调系统的节能率分析[J].流体机械,2020,48(10):71-75.TIAN X N,MAO Y J,LI C M.Energy saving rate analysis of dual cold source cascade air conditioning system[J].Fluid Machinery,2020,48(10):71-75.
- [11]周亚素,陈沛霖.空调冷冻水系统大温差设计的能耗分析[J].建筑热能通风空调,1999(2):18-19.ZHOU Y S,CHEN P L.Preliminary research on the air handing process for double cold source air conditioning system[J].Fluid Machinery,1999(2):18-19.
- [12]田向宁,杨毅,丁德,等.空气冷却除湿过程理论研究[J].暖通空调,2014,44(1):121-124.TIAN X N,YANG Y,DING D,et al.Research on the theory of the air cooled dehumidification process[J].Heating Ventilating & Air Conditioning,2014,44(1):121-124.
- [13]田向宁,李宁.千岛湖地区千岛湖景区双冷源温湿耦合的空调系统研究[J].建筑科学,2017,32(10):171-175.TIAN X N,LI N.Research on the double source temperature and humidity coupling air-condition in qiandao lake[J].Building Science,2017,32(10):171-175.
- [14]田向宁,丁德,杨毅.双冷源空调系统空气处理过程的探讨[J].流体机械,2014,42(9):72-75.TIAN X N,DING D,YANG Y.Preliminary research on the air handing process for double cold source air conditioning system[J].Fluid Machinery,2014,42(9):72-75.