基于建筑储能的变风量空调系统避峰运行控制策略分析
Analysis of Energy Storage Based Strategy of Shifting Peak Operation of HVAC System

王海斌,晋欣桥,孙金龙,杜志敏
WANG Hai-bin,JIN Xin-qiao,SUN Jin-long,DU Zhi-min(Shanghai Jiaotong University

摘要(Abstract):

针对上海地区某一商务楼及其空调系统进行了仿真试验,对系统正常启动和提前启动两种控制策略的仿真结果进行了比较。结果表明,根据气象条件和建筑物的特性适时地提前启动系统,通过利用建筑物热容的能量储存能力可以减小系统的峰值电力需求,降低系统的运行费用同时室内的热舒适性状况未受影响。
An office building in Shanghai is tested with two operation strategies of normal and pre-cooling respectively.The results show that the capacity of building can be used for energy storage.The strategy of suitable pre-cooling schedule based on outdoor conditions and building capacity can reduce the power demand on peak hour and maintain acceptable indoor thermal comfort,and it result in operation cost saving.

关键词(KeyWords): 储能;电力避峰;变风量;空调系统;优化运行控制
energy storage;shifting peak;HVAC;optimal operation strategy

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 王海斌,晋欣桥,孙金龙,杜志敏
WANG Hai-bin,JIN Xin-qiao,SUN Jin-long,DU Zhi-min(Shanghai Jiaotong University

扩展功能
本文信息
服务与反馈
本文关键词相关文章
本文作者相关文章
中国知网