摘要(Abstract):

温湿度独立控制技术是降低大型公共建筑能耗的一种有效的方法。本文从实验的角度,分析了温湿度独立控制的空调系统在不同的设计温差条件下系统能耗的变化规律,以期能为温湿度独立控制空调系统的设计提供参考。
The technique about independent temperature and humidity control is a good method for reducing the energy consumption of air-condition system in large public construction.The changing rules of energy consumption was analyzed in the air-condition system that using this technique when it has a different chilling water temperature difference,we hope these can provide the help to the design of this air-condition system.