PR175.R57N177.TPX/J.型三联柱塞计量泵故障分析与处理
Trouble Analysis and Removal of the Pump with Reciprocating Column Head

余庆生,曹春荣
YU Qing-sheng,CAO Chun-rong(Lanzhou Petroleum and Chemical Corporation

摘要(Abstract):

PR175.R57N177.TPX/J.型三联柱塞计量泵由于本体零部件多,在运行过程中振动剧烈,断轴等故障频繁,严重影响了工厂正常生产。在对该泵进行故障分析的基础上,采取了一些有效措施,使该泵正常运转,满足了工艺生产要求。
PR175.R57N177.TPX/J.pump has three column head with measuring function.Because of its many components or parts,strong vibration,shaft breaking and other troubles,which produced a large threat to normal manufacture.On the basis of meticulous analysis,we take some effective measures,make the pump running well to meet the normal production require.