驻室抽气压缩机及其与风洞性能相关性研究Study on the Compressor Used in Plenum Suction System and It's Corelation with the Wind Tunnel Performance
周恩民,程松,张文,刘恺,熊波,王仪田,施宏博,程超
ZHOU En-min,CHENG Song,ZHANG Wen,LIU Kai,XIONG Bo,WANG Yi-tian,SHI Hong-bo,CHENG Chao
摘要(Abstract):
为了研究驻室抽气压缩机及其与风洞性能的相关性,对E71-3离心压缩机进行了性能试验,并进行了驻室抽气性能测试。试验结果表明:(1)E71-3离心压缩机实测最高压比4.516,设计点多变效率81.8%,达到了设计要求。(2)风洞运行总压升高,压缩机多变效率降低。(3)风洞试验段Ma=0.9~1.1时,驻室抽气量对风洞模型区梯度的影响不大,但驻室抽气量超过4%后风洞马赫数均方根偏差明显增大;压缩机稳定在中等转速、适量抽气量的工况,且入口流量调节阀全开,风洞流场品质较好,运行成本最低。
In order to study the compressor used in plenum suction system and it's corelation with the wind tunnel performance,the performance test of the E71-3 centrifugal compressor and the plenum suction system were conducted. The maximal pressure ratio of the compressor measured in the test is 4. 516 and the polytropic efficiency of the design point is 81. 8% which have all achieved the design requirements. The compressor's polytropic efficiency will decrease as the settling chamber total pressure increase. From Ma0. 9 to Ma1. 1 in wind tunnel test section,the plenum suction mass flow rate has a little effect on the gradient of the Mach number in the wind tunnel model area,the root-mean-square error will increase significantly if the plenum suction mass flow rate more than 4%,the wind tunnel flow quality will be well and the total running power will be lowest when the compressor's rotation and the plenum suction mass flow rate at middle level,and the entrance air flow adjusting valve is fully opened.
关键词(KeyWords):
连续式风洞;驻室抽气;离心式压缩机;性能测试
continuous wind tunnel;plenum suction system;centrifugal compressor;performance test
基金项目(Foundation):
作者(Author):
周恩民,程松,张文,刘恺,熊波,王仪田,施宏博,程超
ZHOU En-min,CHENG Song,ZHANG Wen,LIU Kai,XIONG Bo,WANG Yi-tian,SHI Hong-bo,CHENG Chao
参考文献(References):
- [1]周宁,王晓放,戈仰宗,等.离心式压缩机热力性能实时在线监测系统及软件设计[J].流体机械,2002,30(8):26-28.
- [2]朱锋,郭海涛.离心式压缩机工厂性能测试见证[J].石油规划设计,2009,20:29-31.
- [3]谢进祥.离心式压缩机的性能测试与计算[J].风机技术,2006,(2):6-9.
- [4]JAMES A,GUNN W,MARTINDALE R,et al.Performance evaluation of a transonic wind tunnel compressor[R].AIAA 92-3927.
- [5]郝礼书,乔志德,武洁,等.NF-6风洞AV90-2轴流压缩机喘振曲线测试研究[J].西北工业大学学报,2009,27(4):477-488.
- [6]高超,王娜,袁先士,等.NF-6增压连续式高速风洞压缩机喘振边界的确定[J].实验流体力学,2013,27(5):61-65.
- [7]周恩民,程松,许靖,等.0.6m连续式跨声速风洞AV90-3轴流压缩机喘振边界测试研究[J].实验流体力学,2014,28(5):81-85.
- [8]陈天君.谈轴流压缩机和离心压缩机的喘振试验[J].化学工业与工程技术,2007,28:120-122.
- [9]徐忠.离心式压缩机原理[M].北京:机械工业出版社,1978:22-23.
- [10]李超俊,余文龙.轴流压缩机原理与气动设计[M].北京:机械工业出版社,1985:23-24.
- [11]张智慧,李伟.压电振动给科技术及装置的研究进展[J].包装与食品机械,2013,1(3):55-59.
- [12]周利剑,范远刚,高斌,等.储液罐子结构振动试验仿真分析[J].压力容器,2013,30(7):19-23.
- [13]袁风华,金颖,吴广辉.某高炉用轴流压缩机组异常振动的原因分析及处理[J].流体机械,2015,43(2):48-51.
- [14]崔津,王维民,高金吉,等.多平行轴系离心压缩机振动耦合传递特性研究[J].流体机械,2013,41(12):10-15.
- [15]恽起麟.实验空气动力学[M].北京:国防工业出版社,1994:120-121.
- 连续式风洞
- 驻室抽气
- 离心式压缩机
- 性能测试
continuous wind tunnel - plenum suction system
- centrifugal compressor
- performance test