流体机械

2009, v.37;No.v.37(07) 42-44

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Archive) | 高级检索(Advanced Search)

硫酸泵机械密封失效分析及改造
Failure Analysis and Reformation of Mechanical Face Seal Used in the Frequency Starting Sulfuric Acid Pump

刘华
LIU Hua(Anqin Branch

摘要(Abstract):

针对频繁启动的硫酸泵在实际运行中出现机械密封泄漏问题,进行密封失效分析,提出改造方案,解决了机械密封短期失效问题。
In view of the leakage of mechanical face seal used in the frequency starting sulfuric acid pump,the reasons of failure was analyzed,then reformation scheme was proposed,the final the short-term failure of mechanical face seal was resolved.

关键词(KeyWords): 频繁启动;机械密封;失效分析;改造
frequency start;mechanical seal;failure analysis;reformation

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 刘华
LIU Hua(Anqin Branch