对离心泵试验中常见的误操作现象进行了详细的分析,指出产生这些误操作的原因,提出了解决这些误操作应采取的具体措施,以开式试验台手动试验为例介绍了在性能试验和汽蚀试验中应采取的正确操作程序。
Familiar incorrect manipulation phenomenons of the centrifugal pump test are analyzed,the causes of these incorrect manipulations are indicated,and material measures that should be taken in solving these incorrect manipulations are put forward.Taking the open-type platform manual test for example,correct manipulative programs that should be taken in performance test and cavitation test are introduced.