流体机械

2011, v.39;No.469(07) 1-5

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Past Issue) | 高级检索(Advanced Search)

改变叶轮与蜗壳相对安装位置对双吸多翼风机性能影响的试验研究
Experimental Study on the Effect of Relative Impeller-to-volute Position on the Performance of Multi-blade Centrifugal Fan

杨昕;陈望明;袁民建;温选锋;何明杰;
YANG Xin1,CHEN Wang-ming1,YUAN Min-jian2,WEN Xuan-feng2,HE Ming-jie1(1.Sunwill Precising Plastic Corporation,Shunde 528305,China;2.Xi'an Jiaotong University,Xi'an 710049,China)

摘要(Abstract):

以中央空调末端装置中广泛使用的双吸前向多翼离心风机为研究对象,设计了叶轮与蜗壳安装位置可调的试验装置,试验研究了改变叶轮与蜗壳安装位置对风机性能的影响,并进行了初步的分析。研究结果表明:对于本文研究的风机,叶轮中心与蜗壳几何中心相重合的位置不是最佳位置,两者合适的相对安装位置能使风机在设计转速下风量提高6.08%,总效率提高2.4%,噪声降低0.8dB(A)。
An experimental structure which can adjust the installation positions of the impeller and the volute was devised to investigate the effect of relative impeller-to-volute position on the performance of a multi-blade centrifugal fan which is widely used in the terminal unites of central air conditioning.The results show that the coincident position between the impeller center and the volute geometric center was not conducive to the performance of this test fan.An optimum relative impeller-to-volute position can enhance the volume flow rate and the total efficiency of the fan by 6.08% and 2.4% each,while the sound pressure level was decreased by 0.8dB(A).

关键词(KeyWords): 多翼离心风机;叶轮与蜗壳相对安装位置;试验研究
multi-blade centrifugal fan;relative impeller-to-volute position;experiment study

Abstract:

Keywords:

基金项目(Foundation): 省部产学研结合项目:盘管风机设计方法及节能降噪研究(2009B90300031)

作者(Author): 杨昕;陈望明;袁民建;温选锋;何明杰;
YANG Xin1,CHEN Wang-ming1,YUAN Min-jian2,WEN Xuan-feng2,HE Ming-jie1(1.Sunwill Precising Plastic Corporation,Shunde 528305,China;2.Xi'an Jiaotong University,Xi'an 710049,China)