土壤源热泵垂直单埋管换热性能影响因素研究
Underground Vertical Single Tube Heat Exchange Effect Factors by Soil Source Heat Pump

丁力行,陈季芬,彭梦珑
Ding Lixing Chen Jifen Peng Menglong

摘要(Abstract):

针对影响土壤源热泵垂直埋管单管换热性能的几种因素进行分析研究 ,得到盘管物理特性与换热性能之间的内在联系 ,并利用数值计算方法得到供工程设计参考的优化设计数据。
Effect factors with soil souce heat pump underground vertical single tube exchange were analysed, the inherence relation of tube physical parameters and heat exchange performance was get. For the more, numerical value calculating method was used and the optimizing design data for engineering reference was obtained.

关键词(KeyWords): 埋管;换热;影响因素
underground tube;heat exchang;effect factors