风冷热泵机组部分负荷变工况下优化风量的初步研究Preliminary Study on Air Volume Optimization under Part Load and Variable Operating Condition for Air-cooled Heat Pump
金星,张小松
JIN Xing,ZHANG Xiao-song(Southeast University
摘要(Abstract):
建立了风冷热泵机组冷凝器的数学模型,分析了风量调节方式对COP的影响,得到不同工况不同负荷率下的最优风量变化曲线。结果表明,同负荷率下工况的变化对最优风量比例影响较小,而负荷率的变化对最优风量比例影响较大。针对某特定机组,部分负荷率大于50%时应采用定风量调节,部分负荷率小于50%时应采用变风量调节;部分负荷率为25%时,选用最优风量COP可提高8%。同时,基于模拟结果,对风机选型也提出了新的看法。
The mathematical model of condenser of air-cooled heat pump was built.The influence of adjustment method of air volume to COP was analyzed.The changing curve of optimal air volume under different part load rate and operating conditions was gained.Results showed that the influence of operating condition to optimal air volume was slight;the influence of part load rate to optimal air volume was great.Aimed at one special heat pump,variable air volume adjustment should be used when the part load rate was lower than 50%.Especially,when part load rate was 25%,the COP could increase by 8%.And based on the results,a new idea about selecting fan was presented.
关键词(KeyWords):
风冷热泵机组;变工况;部分负荷;风量调节;模拟
air-cooled heat pump;variable operating condition;part load;air volume adjustment;simulation
基金项目(Foundation):
作者(Author):
金星,张小松
JIN Xing,ZHANG Xiao-song(Southeast University
参考文献(References):
- [1]Yu F W,Chan K T.Advanced control of condensingtemperature for enhancing the operating efficiency ofair-cooled chillers[J].Building and Environment,2005,40:727-737.
- [2]Yu F W,Chan K T.Advanced control of heat rejectionairflow for improving the coefficient of performance ofair-cooled chillers[J].Applied Thermal Engineering,2006,26:97-110.
- [3]张小松,夏?.风冷冷水机组部分负荷时的节能优化运行策略与性能分析[J].暖通空调,2004,34(2):78-82.
- [4]Shi-ming Deng,Jhon Burnett.Performance monitoringand measurement for central air conditioning chillerplants in buildings in Hong Kong[J].HKIE trans,1997,4(1):7-12.
- [5]Yeung Tat Man.Performance evaluation of hotel chil-ler plant[D].Research Project:3.03,Department ofBuilding Services Engineering,The Hong Kong Poly-technic University,2000.
- [6]李苏泷,徐莉.水冷式冷水机组冷凝温度控制法研究[J].制冷学报,2005,26(4):59-62.
- [7]丁国良,张春路.制冷空调装置仿真与优化[M].北京:科学出版社,2001.
- [8]吴业正.小型制冷装置设计指导[M].北京:机械工业出版社,1997.