流体机械

2009, v.37;No.442(04) 60-63

[打印本页] [关闭]
本期目录(Current Issue) | 过刊浏览(Past Issue) | 高级检索(Advanced Search)

低温表面大流量无沸腾喷雾冷却试验研究
Experimental Investigation of Non-boiling Spray Cooling with Low Surface Temperature and Big Water Flow Rate

孙纪远;朱冬生;王正东;涂善东;
SUN Ji-yuan1,ZHU Dong-sheng1,2,WANG Zheng-dong1,TU Shan-dong1 (1.East China University of Science and Technology,Shanghai 200237,China;2.South China University of Technology,Guangzhou 510640,China)

摘要(Abstract):

对低表面温度大流量无沸腾喷雾冷却技术进行了实验研究。实验以水作为冷却工质,在常温常压下进行,流量范围在0.65~1.1L/min间。发现在相同喷雾高度下,喷雾压力越大,喷雾传热性能越好;在一定喷雾高度范围内,喷雾在待冷却表面形成的圆正好与待冷表面相切时,传热性能最优。此时,喷雾压力0.46MPa条件下,表面温度仅31℃时,最大热流密度达到34W/cm2。
Experimental investigation of non-boiling spray cooling with low surface temperature and big mass flux was conducted.At the condition of room temperature and atmospheric pressure,water was used as working medium and water flow rate ranged from0.65-1.1L/min.It shows that the bigger the spray pressure,the better of the heat transfer performance.When the nozzle-to-surface distance is within a certain value,there exists an optimum position where the spray footprint is inscribed to the heated surface.At this position,with spray pressure 0.46MPa and surface temperature 31℃,the heat flux can reach 34W/cm2.

关键词(KeyWords): 喷雾冷却;低温表面;大流量;传热特性
spray cooling;low temperature surface;big water flow rate;heat transfer performance

Abstract:

Keywords:

基金项目(Foundation):

作者(Author): 孙纪远;朱冬生;王正东;涂善东;
SUN Ji-yuan1,ZHU Dong-sheng1,2,WANG Zheng-dong1,TU Shan-dong1 (1.East China University of Science and Technology,Shanghai 200237,China;2.South China University of Technology,Guangzhou 510640,China)